  1. Introduction to Modbus and Modbus Function Codes

    Jan 30, 2023 · Introduction to Modbus and Modbus Function Codes Modbus is one of the oldest industrial communication protocols still in use today. Continue reading to find out how the …

  2. Introduction to Modbus | Digital Data Acquisition and Networks in ...

    Modbus data frames The Modbus communication standard defines a set of commands for reading (receiving) and writing (transmitting) data between a master device and one or more slave …

  3. Modbus Exception Code 04 | Automation & Control Engineering …

    Aug 3, 2007 · I try to communicate CP341 with modbus rtu slave but the response at the funcion code 05 or 15 is always exception code 04. what kind of error is this?? anybody know ???

  4. Making Modbus device communicate with a PC - Control.com

    Jul 26, 2007 · I am learning more about MODBUS, and I would like to know how I make the Modbus device communicate with the PC. Like for example, how do I gather outputs/inputs …

  5. Modbus RTU illegal data address - Control.com

    Sep 5, 2018 · I have 2 PLC controllers and in one controller I have Mapped variables to address 400001, 400002, 400004 and 400005 respectively and 400003 is not mapped. From Master if …

  6. Modbus Coil and register Question - Control.com

    Dec 31, 2008 · The Modbus "registers" are just data values in the slave (server). Section 4.3 (MODBUS Data model) in the "MODBUS Application Protocol Specification V1.1b" discusses …

  7. MODBUS Break Condition & Checksum - Control.com

    Apr 16, 2014 · I'm trying to communicate with a power meter using MODBUS RTU. The cable is only 1 meter long. I have a RS-485 to RS-232 converter connected to a RS-232 to...

  8. How to map floating point values in MODBUS? - Control.com

    May 10, 2004 · If you have floating point values to "present" to a Modbus master I presume you intend your instrument to be a Slave. In this case you would have to respond to a command #3 …

  9. Modbus Time Out Error | Automation & Control Engineering Forum

    Aug 12, 2019 · Modbus slaves can not initiate a transaction - cannot send on their own. The problem could be almost anything - Devices must be Modbus enabled. Just because a device …

  10. Modbus over Ethernet | Automation & Control Engineering Forum

    Jun 25, 2008 · Modbus is a protocol. You can use Modbus protocol over Ethernet, it is then called Modbus TCP/IP. Commonly used by Schneider Electric, as Schneider bought the company …